Skip to content
MajorCooling 07983 878341
Request a quote

F-Gas registered · Hampshire

Services

Designed, installed,
commissioned


Split systems, multi-splits, VRF, ducted ventilation and commercial refrigeration, installed and maintained across residential and commercial sites in Hampshire and the surrounding counties.

Open-plan kitchen with linear slot diffusers set flush into the ceiling

01

Air conditioning


Wall-mounted, ceiling cassette, ducted and floor-standing units. Single splits for a one-room problem, multi-splits running several indoor units from one outdoor, and VRF where a whole building needs heating and cooling at once.

Sized against the actual heat load — glazing, orientation, insulation and occupancy — rather than picked off a chart by room size.

Spiral ductwork routed through a commercial basement at first fix

02

Ventilation


Ducted supply and extract, heat recovery, kitchen and plant room ventilation. Rigid spiral where it needs to hold its shape and insulated flexible where it needs to turn.

Routed early, alongside the other first-fix trades, so ceiling voids stay workable and nothing has to be re-run once the plasterboard is up.

Ceiling fan coil units and insulated flexible ductwork installed at first fix

03

Refrigeration


Commercial cold rooms, cellar cooling and refrigerated display — installed, serviced and leak-checked in line with F-Gas requirements.

Equipment that runs continuously is equipment that fails eventually. Planned maintenance is the difference between a service visit and a lost stock claim.

04

How a job runs


01

Survey

A site visit to measure the rooms, check the fabric and the glazing, and find workable routes for pipework, condensate and power before anything is priced.

02

Design & quote

Equipment sized to the actual heat load, not the room count. A written quote listing the units, the indoor and outdoor positions and what is included.

03

Install

First fix alongside the other trades, then second fix once ceilings and joinery are closed up. Cores drilled, brackets set, condensate falls checked as we go.

04

Commission & certify

Systems pressure-tested, evacuated, charged and run on heating and cooling. Refrigerant logged and paperwork handed over.

05

Service

Planned maintenance to keep filters clean, drains clear and manufacturer warranties valid — with F-Gas leak checks where the charge size requires them.

Get a quote


Tell us the property, the rooms and roughly when you need it done. You will speak to an engineer, not a call centre.

Call 07983 878341